What's New Contact Us
ECP 57 Certified Products Green Seal Certification
Implementing Safer Cleaning Chemicals Environmental Choice Program (ECP-57) Proven More Environmentally Sound

Dell Tech Laboratories is a regulatory consulting firm that has been providing guidance to manufacturers and users of chemical products for over 22 years, with a focus on regulatory compliance, product safety and government registrations. Our services include product assessments, reviews and classification of products under the Hazardous Product Act, both for consumer and industrial workplace regulations. We are a Canadian General Standards Board certified testing laboratory under the requirements of ISO Guide 25. Our clients include small and medium size manufacturers in Canada and the United States as well as large multinational companies.

With greater environmental concerns in today's world, many different standards and criteria have been developed. Two of the more popular standards have been issued by Green Seal Inc. and the Environmental Choice Program. We have compared the Green Seal Industrial and Institutional Cleaners standard GS-37 to the Environmental Choice Industrial and Commercial Cleaners standard ECP-57 below:


Category

Green Seal GS-37

Environmental Choice

Comments

Scope/Product Categories

General Purpose Cleaner, Bathroom Cleaners (excluding toilet bowl disinfectants, sanitizers) Glass Cleaners (excluding sterilizers, disinfectants, sanitizers

Institutional & Industrial: General Purpose, Degreasers, Bathroom Cleaners, Odour Eliminators, Spot & Stain Removers, Glass Cleaners, Neutral Floor cleaners, Hand Soap, Dish Liquid Soap

EC has more categories.

Product Performance Testing

General Purpose – removes 80% of soil in ASTM D4488-95, A5; Bathroom Cleaners – remove 75% of soil ASTM D5345; Glass Cleaners – a rating of 3 in soil removal, smearing, streaking by CSMA test DCC 09

Effective cleaning as measured by CAN/CGSB-2.11-94 Method 20.3

Similar.

Toxic Compounds

Undiluted product not toxic to humans. Toxic if LD50 <2000 mg/kgInhalation lethal concentration < 20 mg/L. Toxicity measured in whole product

Must not contain > 0.1% of any ingredient that is: acutely toxic substance, toxic and bio accumulating,acutely toxic and not biodegradable,bioaccumulating and not biodegradable

Green Seal does not address bioaccumulation.

Carcinogens and Reproductive Toxins

Shall contain only ingredients that are not carcinogens or known to cause reproductive toxins as specified by IARC, NTP, OSHA

Shall not contain carcinogens or reproductive toxins as specified by IARC

Similar.

Skin & Eye Irritation

Undiluted product shall not be corrosive to skin & eyes. Dispensing system products can be tested as used.

Must not be corrosive to skin. pH > 2.0, < 13.0

 

Skin Sensitization

Undiluted shall not be a skin sensitizer. Disp. system conc. shall be tested as used

Not specified

 



Category

Green Seal

Environmental Choice

Comments

Combustibility

Undiluted product shall not be combustible. Flashpoint > 150°F (65.5°C)

Flashpoint > 61°C

EC slightly lower.

Smog/Ozone Production/Indoor Air Quality

Product as used has VOC limits.VOC 1% max for General Purpose, 3% max for Glass Cleaners

VOCs must be < 10% by weight

GS has slightly lower limits.

Toxicity to Aquatic Life

Shall not be toxic to aquatic life. LC50 for algae, daphnia, fish <100 mg/L

Non-toxic to aquatic life by sub chronic toxicity tests at minimum use dilution for algae, daphnia and fish

Similar.

Aquatic Biodegradability

Each organic readily biodegradable by OECD test

Must be readily biodegradable(OECD) whole formulation or each organic ingredient

Similar testing.

Eutrophication

< 0.5% P

<2.2% P

 

Prohibited Ingredients

APEO, dibutyl phthalate, heavy metals, ozone depleting compounds

APEO, aromatic solvents, butoxyethanol, chlorinated solvents, < 5% NTA, < 1% EDTA, ozone depleting products

 


Category

GS -37

Environmental Choice

Comments

Fragrances

Must be identified.

Not specified

 

Concentration

Must be a concentrate.

May be a concentrate or RTU

 

Packaging

Primary package recyclable or may be returned and refilled.L

Not specified

 

Animal Testing

Prefer no animal testing.

Not specified

 

Training

Operators shall be trained in proper use of product including: dilution, use, disposal and use of equipment.

WHMIS and OSHA require training

 

Labels

Labels should assist non-English speaking and illiterate personnel. Labels must indicate dilution with cold water, dilution level, use, disposal and protective equipment

Must be identified as not for household use. Detailed use, disposal and recycling directions, must be used temperature 17C below its flashpoint

Both will have to meet workplace-labeling requirements.


In my expert opinion, GS 37 and ECP 57 are very similar with no material overall differences/impact regarding safety or protection for the environment.

John Ott
Dell Tech Laboratories Ltd.
Senior Business Development Manager

 

 

©copyright Enviro-Solutions 2003-04. All rights reserved.